Brand
Ruud
Series
Achiever® Series
Material
Steel
Finish
Baked Enamel
Dimensions
42-11/16 in L x 31-1/8 in W x 48-13/16
Frequency Rating
60
Phase
3
Number of Stages
2
Refrigerant Type
R-410A
Compressor Type
Scroll
CFM Rating
5000
Tonnage
7.5
Liquid Line Size
1/2
Suction Line Size
1-1/8
Voltage Rating
460V
Amperage Rating
18A
Long Description
RUUD® Commercial Split Compressor Heat Pump Condenser, Achiever® Series, 460 V, 18 A, 60 Hz, 3 ph Phase, 5000 cfm, Scroll Compressor, R-410A Refrigerant, 1/2 in Liquid Line, 1-1/8 in Suction Line, Tonnage: 7.5 ton, 2 Stages, Steel, Finish: Baked Enamel, 42-11/16 in L x 31-1/8 in W x 48-13/16
- All access panels can be opened or removed without affecting the structural strength of the unit stamped louvered panels offer 100% protection for the condenser coil
- Lug for field connection of ground wire
- The contactor is an electrical switch which operates the compressor and outdoor fans Its 24 V coil is activated on a call for cooling or heating
- 75 VA step down-type, from Line to 24 V with resettable circuit breaker
- Help provide starting torque necessary to boost the condenser fan motors to operating speed by directing their stored energy to the starter winding in step with the running winding
- Used when unit is in heating mode to defrost outdoor coil
- To provide compressor protection under abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil and more) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure and more) while eliminating nuisance tripping sometimes experienced with conventional control systems
- Constructed with copper tubes and aluminum fins mechanically bonded to tubes for maximum heat transfer capabilities, all coil assemblies are leak tested up to 550 psig internal pressure
- Control box with separate line and control voltages, as well as compressor and other refrigerant controls are accessible through access panels, an electrical access cover may be opened or removed without affecting normal operation of the unit, condenser fan motors are equipped with molded plugs for easy removal, Louver panels and end access panel can be removed for coil cleaning
- Galvanized steel with weather-resistant baked enamel finish
- The scroll compressor is hermetically sealed with internal high temperature protection and durable insulation on motor windings, the entire compressor is mounted on rubber grommets to reduce vibration and noise
- Used when unit is in heating mode and outdoor coil functions as evaporator
- Minimizes refrigerant migration to compressor sump
- To prevent liquid slugging of compressor
- All field sweat joints are made external of the unit and are located close to the ground for a neat looking installation
- Standard on liquid line and vapor line
- Sized for maximum capacity and efficiency, 24 V coil, energized in heating