Brand
Ruud
Series
RHMV
Connection Type
3/8 in Liquid, 3/4 in Vapor
Material
Steel
Finish
Pre-Painted
Dimensions
17-1/2 in W x 21-11/16 in D x 42-1/2 in H
Frequency Rating
60
Phase
1
Refrigerant Type
R-410A
SEER Rating
20.5
BTU Rating
24000
Wattage
7.03
CFM Rating
600 to 1200
Fuse Rating
15
Voltage Rating
208/240VAC
Amperage Rating
3.4A
HP Rating
1/3
Model
2417SE
Configuration
Modulating
Nominal Capacity
2ton
Long Description
RUUD® Air Handler, Series: RHMV, Model: 2417SE, 2 ton Nominal Capacity, 24000 Btu/hr, 208/240 VAC, 3.4 A, 7.03 kW, 1/3 hp Rating, 60 Hz, 1 ph, 600 to 1200 cfm Rating, Modulating Configuration, 20.5 SEER, 3/8 in Liquid, 3/4 in Vapor Connection Type, R-410A, 15 A Fuse, Steel, Pre-Painted, 17-1/2 in W x 21-11/16 in D x 42-1/2 in H
- EcoNet enabled
- Attractive pre-painted cabinet exterior, rugged wall steel cabinet construction, designed for added strength and versatility
- 1 in foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance
- (4) leg, rubber insulated wire motor mount
- Blower housing with integrated controls, motor and blower, slide-out design for service and maintenance convenience
- Field convertible for vertical upflow, vertical down flow, horizontal left hand or right hand air supply
- Three combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors
- Indoor coil design provides low air side pressure drop, high-performance and extremely compact size
- Coils are constructed of aluminum fins bonded to internally grooved copper tubing, coils are tested at the factory with an extensive refrigerant leak check, coils have copper sweat refrigerant connections
- Coils utilize chatleff metering device connections
- Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils
- Supply duct flanges provided as standard on air handler cabinet
- Provisions for field electrical connections available from either side or top of the air handler cabinet
- Connection point for high voltage wiring is inside the air handler cabinet, low voltage connection is made on the outside of the air handler cabinet
- Concentric knockouts are provided for power connection to cabinet, installer may pull desired hole size upto 2 in for 1-1/2 in conduit
- Front refrigerant and drain connections
- 15-7/8 in W x 19-3/4 in D return air opening
- 3/4 in auxiliary, primary drain connection
- 1st major Series
- 1st minor Series