Brand
Ruud
Series
RHCLP Series
Connection Type
NPT Female
Material
18 ga Sheet Metal
Finish
Galvanized
Dimensions
52 in L x 27 in H
Pressure Rating
450psig
Connection Size
3/4in
Frequency Rating
60
Phase
3
Number of Stages
2
Refrigerant Type
R-410
EER Rating
11
BTU Rating
90000
Wattage
26.4
CFM Rating
3000
Filter Size
(4) 16 x 25 x 1
Fuse Rating
15
Cooling Capacity
90000
Rotational Speed
1750
Liquid Line Size
1/2
Suction Line Size
1-1/8
IEER Rating
12.2
Number of Speeds
2
Voltage Rating
460V
Amperage Rating
3A
HP Rating
2
Nominal Capacity
7.5ton
Long Description
RUUD® Commercial Heat Pump Air Handler, Series: RHCLP Series, 7.5 ton Nominal Capacity, 90000 Btu/hr Cooling, 90000 Btu/hr, 460 V, 3 A, 26.4 kW, 2 hp Rating, 60 Hz, 3 ph, 1750 rpm Rotational Speed, 3000 cfm Rating, 11 EER, 12.2 IEER Rating, NPT Female Connection Type, R-410, 15 A Fuse, 3/4 in Connection, 1/2 in Liquid Line, 1-1/8 in Suction Line, (4) 16 x 25 x 1 in Filter, 2 Stage, 2 Speed, 450 psig, 18 ga Sheet Metal, Galvanized, 52 in L x 27 in H, Additional Information: Belt VFD Low Static Drive
- The pre-painted, sheet metal cabinet uses 18 ga material for structural components with an underlying coat of G60 electro deposition powder-coating that is tested to withstand a rigorous 500 hr salt spray test, per ASTM B117
- Inherently protected motors are mounted inside of insulated cabinet to reduce motor noise
- A choice of motor horsepower's and drive combinations are available to allow you to meet specified CFM at various static pressures up to 2 in external static pressure
- Allows for horizontal installation in most standard drop ceiling applications and the movement of units through most standard doorways for addition or replacement work
- 1 in throwaway filters are standard, but filter racks are designed to accept either 1 in or 2 in filters
- Two circuit, interlaced row split coils are constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities
- All coil assemblies are leak tested up to 450 psig internal pressure prior to installation into units
- Field piping connections are made through a fixed post between two side access panels on either side of the unit
- Allows flexibility to meet most field conditions as well as full accessibility after the installation is complete, units may be used with two straight cool condensing units or single circuit manifolded in the field using the copper fittings shipped with each unit
- Provides two-stage airflow for improved part load efficiency
- The galvanized steel drain pan is designed to trap condensate in either vertical or horizontal installations
- Condensate drain connections are located on both sides of the unit allowing complete flexibility to meet most field conditions
- Two removable panels on top and each side of the unit are easily removed for access to motors, blowers, sheaves and filters
- All Models are designed for either application and can be installed in either position as supplied from the factory
- It has two TX valves with internal check valves that allow reverse flow to occur, providing superior control during heating and cooling cycles
- The RHCLP air handler has been rated and certified to operate with matching size RPCL heat pumps