Brand
Samsung
Material
Steel
Finish
Galvanized
Temperature Rating
63 to 90 deg F, <=86 deg F
Frequency Rating
60
Phase
1
Sound Level
27 dBA, 31 dBA, 34 dBA
Power Rating
84
Drive Type
Inverter
Refrigerant Type
R-410A
EER Rating
11.5
SEER Rating
19
Compressor Type
Twin BLDC Rotary
BTU Rating
12000 Btu/hr, 14000 Btu/hr
CFM Rating
300 cfm, 353 cfm, 399 cfm
Fuse Rating
15
HSPF Rating
9.2
Number of Fan Speeds
3
Voltage Rating
208-230V
Amperage Rating
10.9A
Long Description
Samsung Split System Unit, 208-230 V, 10.9 A, 84 W, 60 Hz, 1 ph, 3 Number of Fan Speeds, 12000 Btu/hr, 14000 Btu/hr, 300 cfm, 353 cfm, 399 cfm CFM Rating, 11.5 EER, 19 SEER, HSPF: 9.2, Twin BLDC Rotary Compressor, R-410A, 15 A Fuse, Inverter Drive, 27 dBA, 31 dBA, 34 dBA, Steel, Galvanized, 63 to 90 deg F, <=86 deg F, 17-5/16 in Overall Length, 35-7/16 in Overall Width, 7-13/16 in Overall Height, Additional Information: 1/4 in, 3/8 in Connection, Slim Duct Single-Zone Duct
- The outdoor unit shall supply power to indoor unit via 14 AWG x 3 power wire
- High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
- Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
- Auto-restart after power loss
- Soft start compressor minimizing current inrush
- All heat exchangers shall be mechanically bonded aluminum fin to copper tube
- The condensing unit heat exchanger salt spray test method ISO 9227 the heat exchanger showed no unusual rust or corrosion development to 500 hr
- Base pan heater equipped as standard indoor fan is sirocco-type
- Three-fan speed settings and auto setting
- Washable filter as standard
- Control wiring shall be two 16 AWG
- No additional interface modules/adapters are required when connecting to Samsung central control options
- The unit shall be operated via a wireless or wired remote control with DDC type signal
- Dual-set temperature support when connected to MWR-WG00UN advanced wired controller or central control options
- Wired or wireless controllers must be purchased separately
- The compressor shall be hermetically sealed, inverter controlled BLDC rotary type
- Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit